Woodward 1503ES-12S5SUC12S
mounting hole center to center Approx.:52mm [2.05"]
Number of Terminals:3
Duty Cycle:Continuous
Replaces Part Number: Yanmar 119233-77932, Yanmar 119233-77931, Woodward 1502ES-12S5SUC12S, Syncro Start 1502ES-12S5SUC12S
Mounting dimension and plug detail as photo show
Fuel Shut Off shutdown solenoid Yanmar 119233-77932 Woodward 1503ES-12S5SUC12S
NEW John Deere Yanmar Shut down solenoid 119233-77932
Yanmar Engines on John Deere & Hyundai
Yanmar 4TNV94L-SFN,4TNV98L-SFN,4TNV106-GGE,R55-7,R60-7,3TNE84
JOHN DEERE,TAKEUCHI, KOMATSU,KUBOTA
1. When installing, pay attention that the arrow on the valve body should be consistent with the flow direction of the medium. Do not install in a place with direct dripping or splashing water. The solenoid valve should be installed vertically upwards;
2. The solenoid valve should be guaranteed to work normally within the 15%-10% fluctuation range of the rated voltage of the power supply voltage;
3. After the solenoid valve is installed, there must be no reverse pressure difference in the pipeline. And it needs to be energized several times to make it suitable for temperature before it can be put into use;
4. Thoroughly clean the pipeline before installing the solenoid valve. The medium should be free of impurities. Install a filter before the valve;
5. When the solenoid valve fails or is cleaned, to ensure the system continues to run, a bypass device should be installed.